Veterinary Anesthesia Machine
Portable Veterinary Operation Instrument Animal Medical Products Anesthesia Machine Supplies. Systems for monitoring the patient’s heart rate, ECG, blood pressure, and oxygen saturation may be incorporated, in some cases with additional options for monitoring end-tidal carbon dioxide and temperature. Breathing systems are also typically incorporated, including a manual reservoir bag for ventilation in combination with an adjustable pressure-limiting valve, as well as an integrated mechanical ventilator, to accurately ventilate the patient during anesthesia.
Portable Veterinary Operation Instrument Animal Medical Products Anesthesia Machine Supplies
A modern anaesthetic machine includes at minimum the following components:
Systems for monitoring the patient’s heart rate, ECG, blood pressure and oxygen saturation may be incorporated, in some cases with additional options for monitoring end-tidal carbon dioxide and temperature.
Breathing systems are also typically incorporated, including a manual reservoir bag for ventilation in combination with an adjustable pressure-limiting valve, as well as an integrated mechanical ventilator, to accurately ventilate the patient during anaesthesia.
Portable anesthesia machine:
The whole machine has no circuit configuration, and anesthesia surgery can be carried out at any time.
Three barometer monitoring to ensure maximum surgical safety
Features
No electricity will be needed, only manual operation
Module rack with polyester medical material, high strength and lightweight.
Superior thin spray technology, delicate color, beautiful and durable.
High precious vaporizers, Halothane, Enflurane, Isoflurane and Sevoflurane could be chosen freely
The main unit is only 2Kg (w/o vaporizer), lightweight and easy to move
With a dedicated handle, could move by hand-pull.
Two gas sources: O2, N2O, suitable for more patient type
Classical CO2 circle absorber with 1 canister, low resistance, minimum gas leakage, 60cmH2O peak pressure solution.
Ventilator (Optional): TH-1, TH-1A
———
ventilation mode: Closed, Semi-closed, Semi-open
Application: 2-100KG animals
Gas source: O2, N2O 0.25Mpa~0.65Mpa
Two tube (O2, N2O): Scope,0—10L/min.With linkage device,O2 concentration not low than 25%
O2 flush: more than 25L/min
Respiratory mode: Manual, Oxygen
TV: 50~2000mL
APL Valve pressure: 0.5-6KPa
Monitoring: Airway pressure, respiratory mode
Three Gauges: one for O2, one for N2O, one for airway pressure